Euljiro 1-ga Stn, Exit 6 · 2 min · This month's offers

Lifting

XERF vs Thermage FLX: How Do They Differ?

November 3, 2026 · 5 min read · By DayBeau Myeongdong

Medically reviewed by Dr. Hyunji Kim, Chief Director · Medically reviewed on 2026-11-06

Short answer

Both are monopolar radiofrequency devices, but Thermage FLX uses a single 6.78 MHz frequency, while XERF combines 6.78 MHz and 2 MHz and offers three depth settings. Which device suits you is decided by your doctor after assessing your skin thickness and areas of concern.

Q1

What do XERF and Thermage FLX have in common?

Both are non-invasive treatments that deliver heat into the skin with monopolar radiofrequency (RF) while cooling the surface. Neither uses incisions or threads, and any change in firmness appears gradually and varies by person.

Their Korean device category is also the same: both are approved by the MFDS as general-purpose electrosurgical units. The wording of the approved purpose, however, differs. For Thermage FLX it is the non-invasive treatment of wrinkles around the eyes and on the face by coagulating tissue with radiofrequency current; for XERF it is coagulating tissue with radiofrequency current, with no separate mention of wrinkle treatment.

XERF is a relatively new device made by Cynosure Lutronic, while Thermage belongs to a line of monopolar RF devices that has been in use for many years. This difference is also reflected in the amount of research discussed below.

Q2

What changes when the frequency is different?

Thermage FLX uses a single frequency of 6.78 MHz. XERF combines two frequencies, 6.78 MHz and 2 MHz, and is described as delivering the two in sequence within a single pulse.

The manufacturer explains that 2 MHz is designed to act on deeper layers of the skin than 6.78 MHz. In a computational modeling and porcine skin study involving manufacturer researchers, 2 MHz produced broader and deeper heating in the fat layer, 6.78 MHz produced more localized heating along the fibrous septa, and combining the two produced pronounced thermal reactions at the junction of the dermis and subcutaneous tissue.

These are results from models and animal skin, and do not necessarily mean the same difference occurs in people. Think of the frequency difference not as a question of which is stronger, but of how the depth and spread of heat are combined.

Q3

How are depth and cooling controlled?

XERF is set using three depths (Shallow, Middle and Deep) and ten energy levels. According to the manufacturer, ICD cryogen cooling and Wave Fit Pulse regulate energy delivery and cooling to help keep the skin surface temperature steady, and the surface temperature for each shot is shown on the device screen and handpiece.

Thermage FLX uses surface cooling together with skin vibration, and the manufacturer explains that AccuREP technology adjusts energy delivery to your skin for each pulse. Both devices use single-use genuine consumables (XERF effectors and Thermage FLX tips), with a size chosen to suit each area.

AspectXERFThermage FLX
EnergyMonopolar radiofrequency (RF)Monopolar radiofrequency (RF)
Frequency6.78 MHz + 2 MHz6.78 MHz
Depth and energy settingsShallow, Middle, Deep; 10 energy levelsAccuREP adjusts energy for each pulse
Cooling and comfortICD cryogen cooling; surface temperature shown for each shotSurface cooling; skin vibration
ConsumablesSingle-use XERF effectorsSingle-use genuine FLX tips
Approved purpose in KoreaCoagulating tissue with radiofrequency currentNon-invasive treatment of wrinkles around the eyes and on the face through tissue coagulation
Options at DayBeau Myeongdong300, 600 shots; Eye XERF 200, 400 shotsFull face 300, 600, 900 shots; eye tip 225, 450 shots

Q4

How does eye-area treatment differ?

For Thermage FLX, wrinkles around the eyes are included in the approved purpose. A dedicated eye tip and a protective eye shield are used, and because the area is delicate, treatment is carried out carefully at the doctor's discretion.

XERF is offered for the eye area as the Eye XERF program. A report has introduced small effectors for the eye area, but its authors themselves describe their observations as still anecdotal. The eye area has thin, delicate skin, so whether it can be treated and which effector and energy settings to use are decided by your doctor.

Q5

Are the sensation and downtime similar?

With both devices you may feel warmth with each shot, and how strongly varies from person to person. XERF protects the skin surface with cryogen cooling, Thermage FLX with surface cooling and vibration. Where needed, topical anesthesia is applied under The Comfort Code, and energy levels are adjusted for your comfort.

After either device, temporary redness, warmth and mild swelling can occur. With Thermage FLX, blisters or crusting may also occur, and after XERF we advise avoiding saunas and jjimjilbang, strenuous exercise and alcohol on the day of treatment. With both, your skin may feel dry afterward, so moisturize well, and if blisters appear within a few days, contact us right away.

Q6

How should I choose?

First, the amount of research differs. The Thermage line has a long research history, such as a 2003 multicenter study of the eye area using an early-generation device. For XERF, published studies include a prospective multicenter study in which 39 people received two sessions and a retrospective review of 16 people, and the authors noted that further research is needed.

In practice, the choice depends on skin thickness and fat volume, where laxity sits, whether the eye area is a concern, and your schedule and any combined treatments. Either device may be combined with other lifting devices or skin boosters in one plan, and the combination, order and interval are decided by your doctor.

At DayBeau Myeongdong, your concerns and schedule are sorted out in a Personal Consultant Session, followed by the Doctor's Treatment Design. Details and prices for each device are on the XERF and Thermage FLX pages.

References

  1. Ko K, Ryu HG, Park J, Kim W, Kim S, Ko J, Cho SB. Computational modeling and histologic analysis of 6.78- and 2-MHz monopolar radiofrequency-induced thermal reactions. Lasers Med Sci. 2025;40(1):501.
  2. Weiss RA, Wang J, DiBernardo B, Bhatia AC. Clinical Outcomes Following Dual-Frequency Noninvasive Monopolar Radiofrequency Treatment for Facial Laxity and Lower Face Lifting: A Prospective Multicenter Study. Cureus. 2026;18(3):e104546.
  3. Erlich G, Dahan E, Wolf Y. Objective and subjective retrospective evaluation of XERF, a novel single-shot dual-frequency non-invasive monopolar radiofrequency. Lasers Med Sci. 2026;41(1):194.
  4. Erlich G, Dahan E, Skorochod R, Wolf Y. Dual-Frequency Non-invasive Monopolar Radiofrequency for Periorbital Tightening: Introduction of Novel Small Treatment Tips. Cureus. 2026;18(1):e101187.
  5. Fitzpatrick R, Geronemus R, Goldberg D, Kaminer M, Kilmer S, Ruiz-Esparza J. Multicenter study of noninvasive radiofrequency for periorbital tissue tightening. Lasers Surg Med. 2003;33(4):232-42.
  6. Cynosure Lutronic. XERF - Structural Skin Tightening.
  7. Thermage (Solta Medical). Thermage | Skin Tightening Treatment.

Related treatments

#XERF#Thermage FLX#dual frequency

Questions about your skin?

Tell us your concern and your travel dates — we'll answer before you book.

Medically reviewed by

Dr. Hyunji Kim, MD

Chief Director, DayBeau Clinic Myeongdong Signature

Medically reviewed on 2026-11-06 · View doctor's profile

This page is general information, not medical advice. Results vary from person to person, and no outcome can be guaranteed. Please confirm suitability, risks and alternatives with a doctor in a one-on-one consultation.

Keep reading

Chat with UsBook an Appointment